• Predictable effluent, TN, TP
    • BNR for low NPDES permits
    • OxyLift, OxyStrip, Dual-Air-Control products
  • Energy Reduction
    • Separate aeration from mixing energy
    • Infinite recycle provides increased MLSSR
  • Redundancy allows for reduced capital cost
    • Anoxic and Anaerobic basins not required
  • Control Scheme & SCADA Monitoring
    • Plant wide SCADA systems
    • LAN for Ethernet communication
  • Load Oriented Oxygen Demand Supply
    • DO (Dissolved Oxygen) Meter Control
    • ORP (Oxidation Reduction Potential) Meter Control
  • Industry max. 8:1 Diffuser Turn Down
    • 2.5 SCFM to 22.0 SCFM range per 2m OxyStrip
    • 4.0 Nm3/h to 36.0 Nm3/h range per 2m OxyStrip
  • 20% to 40% more efficient - reduction of utility cost
    • Installation
      • Retrievable or fixed grid
      • Up to 90% Reduction of pipe & couplings
    • Membrane materials & expected life
      • EPDM, Silicone, & Polyurethane
      • > 10 years
    • One 2m long OxyStrip™ is equal to 9 times 9” disc
      • Retrievable rack
        • Multi-level system redundancy
        • 4.0 Nm3/h to 36.0 Nm3/h range per 2m OxyStrip
      • No retrievability limitation by basin geometry
        • Rectangular, round, toroidal, and square
        • Bridge or wall mounted
        • Diffuser rack retrieval in 2 minutes
          • Rack transfer system for diffuser maintenance
          • Movable hoist and transfer system
        • OxyProcess compatible design
          • Lagoon Aeration
            • Oxidation for BOD removal, NH3 – Nitrification
            • Mixing
          • Mixing & Aeration
            • Area of influence up to 50’ [15m]
            • Depth installed 5’ to 30’ [1.6m to 9m]
          • Deployment Method
            • Floating Pontoons for variable water levels
            • Self-weighted drop in & retrievable rack system
          • Mechanical plants
            • Replacement of aeration equipment
            • Supplemental aeration system
          • Retrofit to existing equipment
          • Membrane materials: EPDM, or Silicone
          • Factory pre-assembled, tested, & certified diffuser modules & grid sections available
          • Fixed grid design only
          • Continual & automatic condensation purge system
          • Biofilm attached growth systems for BOD and nitrogen removal from wastewater
            • Retrievable, drop-in FBBR modules
              • Increasing the BOD removal performance, increase biomass "suspended & fixed" up to 60%
                • Fixed film media units design options
                  • Single pass
                  • Return sludge IFAS systems
                Pioneer of Fine-Bubble
                Social Networks
                © 2023 Copyright Jaeger Aeration