OxyStrip Diffusers

  • 8:1 System Turn Down - Airflow range 2.5 SCFM [4.0 Nm3/h] to 22.0 SCFM [36.0 Nm3/h] per 2m OxyStrip™
  • 20% Higher SOTE over entire design airflow range vs. 9” disc & tube diffuser systems
  • Fine bubble Membrane Materials: EPDM, Silicone, & Polyurethane
  • 1x 2m long OxyStrip™ = 9 times 9” disc diffusers
  • 1x 2m long OxyStrip™ = 2.5 times 1m long tube diffusers
  • Reduction of pipe joints & couplings needed by Factor 9 times
  • Retrievable & fixed diffuser grid design options
  • Expected diffuser membrane life > 10 years; reusable diffuser body – replace only membrane
Oxy Strip

Show Media

OxyLift Design

  • Wall mounted & bridge mounted OxyLiftTM diffuser rack option
  • Overcome basing width limitation of retrievability with OxyLiftTM bridge design, diffuser rack retrieval, transfer, & movable host and transfer system
  • New construction: Single aeration tank design option - capital investment savings by eliminating the need for tank redundancy
  • 8:1 System Turn Down - 12 pair OxyLift™ / OxyStrip™ diffuser rack - Airflow range 48.0 SCFM [72.0 Nm3/h] to 384.0 SCFM [616.0 Nm3/h]
  • One OxyLift™ with 24 OxyStrip™ diffusers = 162 9” disc diffusers
  • One OxyLift™ with 24 OxyStrip™ diffusers = 50 x 1m long tube diffusers
  • Fine bubble Membrane Materials: EPDM, Silicone, & Polyurethane
  • Expected diffuser membrane life > 10 years; reusable diffuser body – replace only membrane
oxy strip

Show Media

OxyProcess Design

  • Retrievable OxyLift and OxyStrip diffusers for lowest O&M costs
  • Mixing separated by energy efficient submersible mixers
  • 40 % Power Savings / Energy Conservation over conventional 9” disc & tube diffuser systems due to:
    • 85% power cost reduction - low energy mixing with submerged low speed mixers vs. diffuser air mixing
    • Airflow range 2.5 SCFM [4.0 Nm3/h] to 44.0 SCFM [72.0 Nm3/h] per 2m OxyStrip™ Dual-Air-Control™ pair
    • 16:1 Dual-Air-Control™ system turn down
  • 30% of total investment cost reduction of the activated sludge WWT process stage (diffuser system & concrete tank construction-single tank design option) over conventional fixed grid aeration and tankage systems
  • Optimized energy conserving design for 30+ yrs. projected WWT plant capacity sizing
Oxy Process

Show Media

BioCube Process

  • Biofilm attached growth systems for BOD (biochemical oxygen demand) and nitrogen removal from wastewater. The retrievable
  • Fixed film media units design options:
    • Single pass (fixed bed reactor)
    • Return sludge IFAS (Integrated fixed film activated sludge) systems.
  • Retrievable, drop-in FBBR (fixed bed bio reactor) modules
  • Increasing the BOD removal performance / increase biomass (suspended & fixed) by up to 60% by tank volume
oxy tube

Show Media

OxyDisc Diffusers

  • 9” disc EPDM fine bubble membrane disc diffusers – industry standard for 40 years - invented by JAEGER in 1980ies - the world’s 1st EPDM fine bubble membrane disc diffuser
  • OxyDiscTM - ECO-10 - Enhanced fine bubble membrane disc diffuser design vs. 9” disc:
    • 7 ECO-10 disc diffusers = 9 - 9” disc diffusers
    • 20% reduction of in tank installation time & labor cost
  • Fixed grid design only
  • Membrane materials: EPDM, or Silicone
  • Continual & automatic condensation purge system
  • Factory pre-assembled, tested, & certified diffuser modules & grid sections available
Oxy Disc

Show Media

OxyTube Diffusers

  • High efficiency fine Bubble membrane tube diffuser
  • 2 times 1m long OxyTube™ diffusers pair = 5 x 9” disc diffusers
  • Up to 10% Higher SOTE over entire design airflow range
  • Up to 10% Power Savings / Energy Conservation over conventional 9” disc \ systems
  • Reduce lateral air distribution piping and number of diffusers components needed by Factor 3x vs. 9” disc diffusers systems
  • Fixed grid & retrievable fine bubble membrane diffuser system
Oxy Tube

Show Media